Skip to product information
1 of 1

Sentera 6X Calibrated Reflectance Panel Kit

Sentera 6X Calibrated Reflectance Panel Kit

Regular price $400.00
Regular price Sale price $400.00
Sale Sold out
Shipping calculated at checkout.

SKU:S-SEN-6X-REFLP-KIT

SKU S-SEN-6X-REFLP-KIT MPN 21226-00
  • Consistent reflectance reference improves multispectral data accuracy
  • Supports calibration across visible and near-infrared bands
  • Designed for pre- and post-flight reference image capture
  • Enables calibrated five-band multispectral TIFF outputs
  • Integrates into FieldAgent Desktop processing workflows
  • Compatible with Sentera 6X multispectral payloads
  • Supports Sentera 6X Thermal calibration workflows
  • Works with DJI Mavic 3 Multispectral systems

11 total reviews

View full details
  • Description
  • Specifications
  • In the Box
  • FAQ

Sentera 6X Calibrated Reflectance Panel Kit: Reliable reference for accurate multispectral data

The Sentera 6X Calibrated Reflectance Panel Kit is a precision accessory designed to improve the accuracy and consistency of multispectral aerial data. By providing a stable reflectance reference across visible and near-infrared spectral bands, the panel helps compensate for changing ambient lighting conditions. When used as part of a structured capture and processing workflow, it supports calibrated reflectance outputs suitable for professional analysis. This kit is intended for operators who rely on repeatable, analysis-ready multispectral data from Sentera sensors and compatible aircraft platforms.

Key features

  • Stable reflectance surface: Supports calibration across visible and near-infrared spectral bands.
  • Ambient light correction support: Helps compensate for changing illumination conditions.
  • Reference capture workflow: Designed for imaging before and after data collection.
  • Multispectral accuracy improvement: Reduces variability between flights and surveys.
  • Processing workflow support: Used during reflectance calibration in post-processing.
  • Five-band calibrated outputs: Enables calibrated multispectral TIFF generation.
  • Accessory-based calibration: Adds accuracy without modifying sensor hardware.
  • Purpose-built design: Intended specifically for multispectral reflectance workflows.

Improved data consistency under changing lighting conditions

Capturing reference images of the calibrated reflectance panel immediately before and after a mission allows lighting variability to be accounted for during post-processing. This approach helps normalize multispectral data affected by sun angle changes, cloud cover, or shifting illumination. By anchoring imagery to a known reflectance reference, operators can improve consistency within a single dataset and across repeat missions. This is particularly valuable for applications requiring temporal comparison and quantitative analysis.

Calibrated multispectral outputs through FieldAgent Desktop processing

When included in a FieldAgent Desktop workflow, reflectance panel imagery is used during mosaic generation to produce calibrated multispectral outputs. The resulting five-band TIFF contains reflectance-calibrated data for each spectral band. This allows analysis to be based on standardized reflectance values rather than relative pixel intensity. For professional users, this supports more reliable analytics and improved comparability across surveys.

Compatibility with Sentera and DJI multispectral systems

  • Sentera payload support: Compatible with Sentera 6X multispectral sensors.
  • Aircraft compatibility: Works with DJI Mavic 3 Multispectral platforms.

Multispectral workflows requiring calibrated reflectance data

  • Precision agriculture analysis: Improve reliability of vegetation index calculations.
  • Crop monitoring programs: Support consistent results across repeat surveys.
  • Environmental monitoring: Reduce lighting-driven variability in datasets.
  • Research data collection: Enable standardized reflectance-based analysis.
  • Multispectral mapping: Improve accuracy of reflectance-based mosaics.
  • Temporal change analysis: Support comparisons across time and conditions.
  • Survey quality control: Add calibration reference to multispectral missions.
  • Data-driven decision making: Improve confidence in analytical outputs.

Reflectance calibration support for repeatable enterprise surveys

The Sentera 6X Calibrated Reflectance Panel Kit is designed to integrate cleanly into professional multispectral workflows without adding operational complexity. As a passive reference tool, it complements existing sensors and aircraft while supporting consistent data quality over time. Its role in reflectance normalization makes it well suited for repeat surveys, monitoring programs, and analytics-driven operations where consistency is critical.

The panel kit provides a practical way to improve multispectral data reliability across missions. It is a valuable addition for teams seeking calibrated, comparison-ready datasets without changing their sensing hardware.

Available from DSLRPros, supporting professional UAV teams with proven multispectral workflows and calibration expertise. Strengthen your data accuracy with a trusted reflectance reference tool.

  • Compatible with Sentera 6X Thermal Sensor, Sentera 6X Thermal Pro Sensor, and Mavic 3 Multispectral
  • 1x Sentera 6X Calibrated Reflectance Panel Kit
Is this panel compatible with sensors other than the Sentera 6X?

It’s designed and calibrated specifically for Sentera 6X sensors. For other sensors, check compatibility or contact our team.

How do I use the panel during a flight mission?

Place the panel in the field before or after your mission. Capture an image of the panel with the 6X sensor under the same lighting conditions as your flight.

Does it come with calibration certificates?

Yes. Each panel includes factory-issued calibration data and documentation for integration into your post-processing workflow.

How often should I replace or recalibrate the panel?

Panels are built for long-term use, but heavy wear or exposure to harsh conditions may reduce accuracy over time. Replace if surfaces show visible degradation or consult Sentera for recalibration options.

Can this be used for drone compliance reporting?

While the panel aids in data accuracy, it is not a compliance tool. It enhances scientific and agronomic data precision for analysis and reporting purposes.