{"product_id":"airins-sniffer4d-nano-2-plus-base-unit","title":"AIRINS Sniffer4D Nano 2 Plus Base Unit","description":"\u003ch2\u003eSniffer4D Nano 2 Plus Base Unit: Configure Five Modular Slots for Mission-Specific Gas Detection\u003c\/h2\u003e\n\u003cp\u003eThe Sniffer4D Nano 2 Plus Base Unit is a modular gas detection and mapping platform built for the DJI Matrice 4 series and DJI Dock 3, giving field crews a way to sense up to six airborne gas parameters in a single flight. Five internal module slots accept sensors for particulate matter, ozone, carbon monoxide, hydrogen sulfide, ammonia, and more, so the same base unit adapts to whatever gas hazard a mission calls for.\u003c\/p\u003e\n\u003cp\u003eBuilt for UAS operators running pipeline inspections, landfill surveys, HAZMAT response, and industrial air quality surveys, the base unit weighs roughly 8.5 ounces (240 grams) and mounts directly to the aircraft E-Port with no external wiring required. Integration kits extend the same unit to the Matrice 400, Matrice 4E and 4T, and Matrice 350 and 300 for crews running mixed fleets.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFive slots: mix sensors for up to six gas parameters.\u003c\/li\u003e\n\u003cli\u003eIP55 rating: operates safely in wet field conditions without extra housing.\u003c\/li\u003e\n\u003cli\u003eDirect E-Port mount: connects instantly to Matrice 4D and 4TD.\u003c\/li\u003e\n\u003cli\u003eOnboard weather sensor: tracks temperature, humidity, and pressure in real time.\u003c\/li\u003e\n\u003cli\u003eEncrypted data retrieval: stores twelve hours of mission data offline.\u003c\/li\u003e\n\u003cli\u003eSix status LEDs: monitor sensors, GNSS, storage, and aircraft link remotely.\u003c\/li\u003e\n\u003cli\u003eOnboard 32GB storage: retains complete mission logs in CSV format.\u003c\/li\u003e\n\u003cli\u003eSwarm capability: multiple units report data to one shared visualization terminal.\u003c\/li\u003e\n\u003cli\u003eDJI Pilot integration: view and control readings from the remote controller.\u003c\/li\u003e\n\u003cli\u003eActive air intake: shortens response time for faster gas readings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"position: relative; width: 100%; padding-bottom: 56.25%; text-align: center;\"\u003e\u003ciframe style=\"position: absolute; top: 0; left: 50%; transform: translateX(-50%); width: 100%; height: 100%;\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/BgCnozaj_LE?si=gDU6v7TYEIxGJ-dn\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003ch3\u003eConsistent Data in Any Condition\u003c\/h3\u003e\n\u003cp\u003eConsistent readings start with hardware built to hold up in the field. The Base Unit pairs an IP55 rated housing with an active air intake, so gas reaches the sensor chamber fast even in wind or light rain. Encrypted data transmission runs at 1Hz, and a twelve hour retrieval buffer protects mission data if cellular signal drops mid flight.\u003c\/p\u003e\n\u003cp\u003eSwarm support lets fleet operators monitor multiple units from a single terminal, while the onboard 32GB card backs up every reading locally. That combination of speed, redundancy, and fleet visibility means fewer repeat flights and more defensible field data.\u003c\/p\u003e\n\u003ch3\u003eCompatibility and System Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMatrice 4D\/4TD (hardware included): connects to the aircraft's E-Port, Dock 3 ready.\u003c\/li\u003e\n\u003cli\u003eMatrice 400 Integration Kit (sold separately): mounts the base unit via bracket.\u003c\/li\u003e\n\u003cli\u003eMatrice 4E\/4T Integration Kit (sold separately): pairs unit with matching mounting bracket.\u003c\/li\u003e\n\u003cli\u003eMatrice 350\/300 Integration Kit (sold separately): extends compatibility to older Matrice airframes.\u003c\/li\u003e\n\u003cli\u003eDJI FlightHub 2 (third party software): enables remote monitoring and payload control.\u003c\/li\u003e\n\u003cli\u003eDJI Pilot 2 (included with DJI remote controller): displays live gas readings.\u003c\/li\u003e\n\u003cli\u003eAIRINS.ai platform (included, perpetual license): processes mission data into structured reports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications and Use Cases\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOil and gas inspection: screen pipelines and facilities for gas leaks.\u003c\/li\u003e\n\u003cli\u003eLandfill monitoring: track methane and odor emissions across active sites.\u003c\/li\u003e\n\u003cli\u003eHAZMAT response: identify hazardous gas concentrations before crews enter site.\u003c\/li\u003e\n\u003cli\u003eAmbient air monitoring: map particulate matter and pollutant levels citywide.\u003c\/li\u003e\n\u003cli\u003eIndustrial site surveys: verify emission compliance across manufacturing and chemical facilities.\u003c\/li\u003e\n\u003cli\u003eShip fuel monitoring: check sulfur content from vessel exhaust plumes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoosing the Right Sensor Modules for Your Mission\u003c\/h3\u003e\n\u003cp\u003eThe Sniffer4D Nano 2 Plus Base Unit ships empty, so picking the right modules for your five slots is what actually defines the mission it can run. The table below breaks down each available module by detection method, range, and sensitivity, so you can match hardware to the gas hazard you are chasing.\u003c\/p\u003e\n\u003cstyle\u003e\n  .fb-wrap {\n    width: 100%;\n    max-width: 1200px;\n    margin: 0 auto;\n    padding: 0 15px;\n    box-sizing: border-box;\n    color: #1f2937;\n  }\n  .fb-wrap *,\n  .fb-wrap *::before,\n  .fb-wrap *::after { box-sizing: border-box; }\n  .fb-scroll {\n    width: 100%;\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n    border: 1px solid #dce3eb;\n    border-radius: 8px;\n    margin: 20px 0 0;\n  }\n  .fb-table {\n    width: 100%;\n    min-width: 680px;\n    table-layout: fixed;\n    border-collapse: collapse;\n    background: #ffffff;\n  }\n  .fb-table th,\n  .fb-table td {\n    padding: 13px 14px;\n    border: 1px solid #dce3eb;\n    text-align: left;\n    vertical-align: top;\n    font-size: 13px;\n    line-height: 1.5;\n    overflow-wrap: anywhere;\n  }\n  .fb-table thead th {\n    background: #0e2a4e;\n    color: #ffffff;\n    font-size: 13px;\n  }\n  .fb-table thead th:first-child {\n    width: 200px;\n    background: #08182f;\n  }\n  .fb-table tbody th {\n    width: 200px;\n    background: #f4f7fa;\n    color: #0e2a4e;\n    font-weight: 700;\n  }\n  .fb-table tbody tr:nth-child(even) td { background: #f8fafc; }\n  .fb-table.sticky-col thead th:first-child,\n  .fb-table.sticky-col tbody th {\n    position: sticky;\n    left: 0;\n    z-index: 2;\n    box-shadow: 2px 0 4px -1px rgba(0,0,0,0.10);\n  }\n  .fb-table.sticky-col thead th:first-child { z-index: 3; }\n  .fb-table tbody tr {\n    transition: background-color 0.15s ease, box-shadow 0.15s ease, transform 0.15s ease;\n  }\n  .fb-table tbody tr:hover {\n    background-color: #ffffff;\n    box-shadow: 0 4px 12px rgba(0,0,0,0.10);\n    transform: translateY(-1px);\n    position: relative;\n    z-index: 1;\n  }\n  .fb-table tbody tr:hover td,\n  .fb-table tbody tr:hover th { background-color: #ffffff; }\n  .fb-scroll-note {\n    margin: 10px 0 24px;\n    color: #6b7280;\n    font-size: 13px;\n    font-style: italic;\n  }\n  @media screen and (max-width: 749px) {\n    .fb-table { min-width: 560px; }\n    .fb-table thead th:first-child,\n    .fb-table tbody th { width: 150px; }\n    .fb-table th,\n    .fb-table td { padding: 9px 10px; font-size: 12px; }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"fb-wrap\"\u003e\n\u003cdiv class=\"fb-scroll\"\u003e\n\u003ctable class=\"fb-table sticky-col\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eModule\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetection Method\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRange\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eLimit of Detection\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBest For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePM 1.0, 2.5, 10 (Particulate Matter)\u003c\/th\u003e\n\u003ctd\u003eLight scattering\u003c\/td\u003e\n\u003ctd\u003e5 to 1,000 μg\/m³\u003c\/td\u003e\n\u003ctd\u003e5 μg\/m³\u003c\/td\u003e\n\u003ctd\u003eGeneral environmental monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTSP \/ PM 100 (Total Suspended Particulates)\u003c\/th\u003e\n\u003ctd\u003eLight scattering\u003c\/td\u003e\n\u003ctd\u003e30 to 3,000 μg\/m³\u003c\/td\u003e\n\u003ctd\u003e50 μg\/m³\u003c\/td\u003e\n\u003ctd\u003eGeneral environmental monitoring. Uses all 5 internal slots as a standalone build, cannot pair with other modules.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eO3+NO2 (Ozone and Nitrogen Dioxide)\u003c\/th\u003e\n\u003ctd\u003eElectrochemistry\u003c\/td\u003e\n\u003ctd\u003e0 to 11 ppm\u003c\/td\u003e\n\u003ctd\u003e10 ppb\u003c\/td\u003e\n\u003ctd\u003eGeneral environmental monitoring, photochemical oxidant tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNO2 (Nitrogen Dioxide)\u003c\/th\u003e\n\u003ctd\u003eElectrochemistry\u003c\/td\u003e\n\u003ctd\u003e0 to 11 ppm\u003c\/td\u003e\n\u003ctd\u003e10 ppb\u003c\/td\u003e\n\u003ctd\u003eGeneral environmental monitoring, HAZMAT response, ship fuel sulfur monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCO (Carbon Monoxide)\u003c\/th\u003e\n\u003ctd\u003eElectrochemistry\u003c\/td\u003e\n\u003ctd\u003e0 to 11 ppm\u003c\/td\u003e\n\u003ctd\u003e0.05 ppm\u003c\/td\u003e\n\u003ctd\u003eGeneral environmental monitoring, HAZMAT response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSO2 (Sulfur Dioxide)\u003c\/th\u003e\n\u003ctd\u003eElectrochemistry\u003c\/td\u003e\n\u003ctd\u003e0 to 15 ppm\u003c\/td\u003e\n\u003ctd\u003e0.03 ppm\u003c\/td\u003e\n\u003ctd\u003eGeneral environmental monitoring, HAZMAT response, ship fuel sulfur monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eH2S (Hydrogen Sulfide)\u003c\/th\u003e\n\u003ctd\u003eElectrochemistry\u003c\/td\u003e\n\u003ctd\u003e0 to 90 ppm\u003c\/td\u003e\n\u003ctd\u003e0.03 ppm\u003c\/td\u003e\n\u003ctd\u003eGeneral environmental monitoring, oil and gas leak detection, HAZMAT response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNH3 (Ammonia)\u003c\/th\u003e\n\u003ctd\u003eElectrochemistry\u003c\/td\u003e\n\u003ctd\u003e0 to 100 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eOdor detection, HAZMAT response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOU (Odor Unit)\u003c\/th\u003e\n\u003ctd\u003eElectrochemistry\u003c\/td\u003e\n\u003ctd\u003e0 to 10 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eOdor detection, general environmental monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTVOC (Total Volatile Organic Compounds)\u003c\/th\u003e\n\u003ctd\u003ePhotoionization\u003c\/td\u003e\n\u003ctd\u003e0 to 50 ppm\u003c\/td\u003e\n\u003ctd\u003e0.02 ppm\u003c\/td\u003e\n\u003ctd\u003eGeneral environmental monitoring, oil and gas leak detection, HAZMAT response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHCHO (Formaldehyde)\u003c\/th\u003e\n\u003ctd\u003eSolid state electrochemistry\u003c\/td\u003e\n\u003ctd\u003e0 to 100 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eContact DSLRPros support for more information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"fb-scroll-note\"\u003eScroll horizontally to view all columns on smaller screens.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eTwo configurations replace all five slots rather than filling one: the standalone TSP\/PM 100 module and the separate Sniffer4D Nano 2 Plus Methane unit, which uses multi-pass TDLAS technology for dedicated methane screening. The optional External Measurement Module for wind, temperature, and humidity mounts separately and is not part of the five-slot module family. Talk to DSLRPros about your target gases before ordering so your slot configuration matches the mission.\u003c\/p\u003e\n\u003cp\u003eThe Sniffer4D Nano 2 Plus Base Unit exists to give UAS crews a single, reconfigurable sensor platform instead of a different device for every gas hazard. By keeping detection modular and data encrypted end to end, it holds up across pipeline surveys, landfill checks, and emergency response without demanding a new learning curve each time.\u003c\/p\u003e\n\u003cp\u003eDSLRPros helps you configure every Sniffer4D Nano 2 Plus Base Unit before it ships, confirming module selection and integration kit fit against your specific Matrice platform. Our technicians have supported UAS crews across Public Safety, Industrial Inspection, and Environmental Monitoring for decades, so you get a configuration that matches your mission on day one.\u003c\/p\u003e\n\u003cp\u003eOrder the Sniffer4D Nano 2 Plus Base Unit from DSLRPros and get your gas detection payload flight ready fast.\u003c\/p\u003e","brand":"AIRINS","offers":[{"title":"Default Title","offer_id":47966326751462,"sku":"S-AIN-S4D-N2P-BASE","price":2744.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0699\/2769\/8662\/files\/AIRINSSniffer4DNano2PlusBaseUnit.webp?v=1783653638","url":"https:\/\/www.dslrpros.com\/products\/airins-sniffer4d-nano-2-plus-base-unit","provider":"DSLRpros","version":"1.0","type":"link"}